Follow us :

API steel pipe

API steel pipe
group name
ERW API steel pipe/tube
Min Order
10 piece
brand name
TYTSTEEL
Nearest port for product export
TIANJIN XINGANG PORT, QINGDAO PORT, SHANGHAI PORT, NINGBO PORT
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, CPT, DDP, DDU
Acceptable payment methods
T/T, L/C, D/P D/A, MoneyGram, Credit Card, Westem Union, Escrow
update time
Fri, 06 Mar 2015 15:15:21 GMT

Paramtents

  • Technique Hot Rolled

Packging & Delivery

  • Min Order10 piece

Briefing

OD: 21.3mm- 610mm
W.T: 1.0mm - 25mm
Length: 5.8- 13.5m

Detailed


OD: 21.3mm- 610mm
W.T: 1.0mm - 25mm
Length: 5.8- 13.5m

 

ASTM A106/A 106M-08 Tensile Requirements
     Grade A Grade B Grade C   
Tensile Strength,min,psi(MPa)  48 000 {330} 60 000 {415} 70 000 {485}   
Yield Strength,min,psi(MPa)  30 000 {205} 35 000 {240} 40 000 {275}   
     LongitudinalTrabsverseLongitudinalTrabsverseLongitudinalTrabsverse  
Elongation in 2 in. [50 mm], min, %:         
Basic minimum elongation transverse strip tests, and for all small35253016.53016.5  
sizes tested in full section          
             
When standard round 2-in. [50-mm] gage length test specimen is282022122012  
used            
For longitudinal strip tests  A A A   
For transverse strip tests, a deduction for each 1⁄32-in. [0.8-mm] 1.25 1 1  
decrease in wall thickness below 5⁄16 in. [7.9 mm] from the basic        
minimum elongation of the following percentage shall be made        
             
A The minimum elongation in 2 in. [50 mm] shall be determined by the following equation:      
e 5 625 000A0.2 / U 0.9           
for inch-pound units, and          
e 5 1 940A0.2 / U 0.9           
for SI units,           
where:            
e = minimum elongation in 2 in. [50 mm], %, rounded to the nearest 0.5 %,       
A = cross-sectional area of the tension test specimen, in.2 [mm2], based upon specified outside diameter or nominal specimen width and specified wall thickness,
rounded to the nearest 0.01 in. 2 [1 mm2]. (If the area thus calculated is equal to or greater than 0.75 in. 2 [500 mm2], then the value 0.75 in.2 [500 mm2] shall
be used.), and           
U = specified tensile strength, psi [MPa].         

IMG_1394.jpgIMG_1395.jpgIMG_1397.jpg